Air Compressors for Dental Clinics
Technical Guide

Air Compressors for Dental Clinics

Technical Article
18 min read
Dental

Dental clinic compressed air is completely different from factory use. This air goes into patients' mouths. Whatever problems the air has, patients suffer the consequences.

Oil-Free Is Absolute Rule

German Dürr Dental and Italian Cattani have been making dental compressors for decades. Product lines have zero oil-flooded models. Domestic manufacturers making dental air equipment like Shandong Hongrun are the same. All oil-free across the board. This isn't coincidence. It's industry consensus.

New clinic owners almost all ask the same question: oil-flooded machines are so much cheaper, can't you just add a good filter downstream? This idea gets tried every year. Every year people regret it.

When oil-flooded compressor runs, lubricating oil turns into two things mixed into compressed air: oil droplets and oil vapor. Oil droplets are small liquid beads. Filters can catch them. Oil vapor is gaseous molecules, mixed with air. Filter element can't grab it at all. Must rely on activated carbon adsorption. Activated carbon saturates. After saturation, adsorption capability is gone. Oil vapor passes straight through. Filter element should be changed but wasn't, or replaced with cheap stuff, oil goes into patient's mouth. Clinic sees dozens of patients a day, over ten thousand visits a year. This kind of thing happens once and it's an incident.

Oil-free scroll compressor

Scroll machines are absolute mainstream in current dental market. Cattani's AC series, Dürr's Tornado series, domestic Hongrun's scroll machines, all take this technology route. Two scroll plates meshing and rotating to compress air. No piston reciprocating impact type vibration. Sound is light. Failure rate is low.

Oil-free piston machines are cheap. Small clinics consider them. Loud noise is hard disadvantage. Seventy-some decibels. Must find separate room to lock it in. Scroll machine fifty-some decibels. Put one in room next to treatment room, close the door and basically can't hear it. Budget difference of $1,000-2,000, choosing scroll machine is much less hassle.

Dental Handpieces Are Pickier Than You Think

High speed dental handpiece head has a tiny turbine. Compressed air pushes turbine to spin. 300,000 to 400,000 rpm. Turbine chamber precision is very high. Whatever problems the air has, it can all reflect. Experienced dentists can judge air source condition from handpiece sound. Sound is muffled, speed unstable, 80% chance it's air having problems.

One imported high speed handpiece costs several hundred dollars. Using dirty air, wear will be much faster. Some clinics change handpieces frequently. Not necessarily from heavy use. Could be air source problem that was never discovered. Oil mist hurts bearings. Water makes speed fluctuate high and low. Both of these need to be cleaned up at air source.

Three-way syringe gets used even more than handpiece. Blowing cavity dry before filling. Cleaning tooth surface moisture and saliva before cementing crown. Taking impressions has even higher dryness requirements. Airflow carrying oil smell or spraying with water droplets, all the prep work before was for nothing.

Working pressure around 90 psi. Single chair peak flow under 35 CFM.

Where Water Comes From

When air is compressed temperature rises. Cooling down, water vapor condenses into water droplets. 90 psi compressed air can precipitate about 0.4 oz of water per cubic foot. Adds up. Without treatment, will squirt out from three-way syringe nozzle.

Refrigerated dryer is standard configuration. Brings compressed air temperature down, water condenses and drains out, dew point controlled at 37-40°F. Membrane dryer is even smaller. Uses hollow fiber membrane to separate water vapor. No electricity, no refrigerant. Many integrated cabinets stuff this type inside. Membrane dryer consumes part of the air for purging. Loses ten-something percent. Dental air usage is small to begin with. This loss is acceptable.

Many clinics don't pay attention to condensate drainage. Drain valve at bottom of air receiver, week goes by without anyone thinking to open it. Water sitting in there long enough carries out rust flakes, actually contaminates the system. Drain once every morning before starting up. Few seconds.

Filters

Dryer handles water. Filters handle particles and bacteria. Coarse filter catches dust and rust flakes. Precision filter at 0.01 micron handles fine particles. Activated carbon absorbs odors. Terminal sterilizing filter blocks bacteria.

Filter elements are consumables. When buying equipment, ask clearly about element prices. Some brands have cheap machines but expensive elements. Total cost may not be a good deal. Coarse and precision filters change annually. Activated carbon and sterilizing elements change every six months. Element clogged, pressure drop increases, compressor load increases and wastes electricity. Clogged badly, the dirt accumulated inside might even break loose. Worse than not having one installed.

Air Receivers and Integrated Units

Dental air receivers need inner wall anti-corrosion treatment or use stainless steel. Industrial tanks with that layer of rust-preventive paint don't work. Use few years, paint peels and starts rusting. Rust flakes enter air path. Air receivers are pressure vessels. Need periodic inspection. Different regulations in different places. When it's time to inspect, don't delay.

Market dental air systems are overwhelmingly integrated unit form. Compressor, dryer, filters, air receiver packaged in one cabinet. Takes up just over ten square feet. Connect power and air line and it's ready to use. Cattani, Dürr, Hongrun products are basically this format. Separate component configuration occasionally seen in large dental hospitals. Regular clinics don't need the hassle.

What Size to Buy

Calculate by number of chairs. One chair peak air usage 18 to 35 CFM, times simultaneity factor around 0.6. Three chairs, buy 90 to 105 CFM machine is enough. Five or six chairs, buy 140-175 CFM, or two small ones in parallel. Two in parallel has benefit of backup. One breaks, other can hold the fort.

Buying too small is more trouble than buying too big. Compressor long-term full load running, shorter life, noise also gets louder.

Industrial Oil-Free Machines Can't Be Used

Some clinic owners see on the internet brands like Jaguar, Kaishan, Fusheng, these industrial oil-free machines. Price is only half or even one-third of dental-specific machines. Gets their attention.

Two types of equipment have different standards. Industrial oil-free machines meet industrial air standards. Air receiver inner wall treatment, included filter specs, material selection all follow industrial requirements. Dental compressors are medical devices. Need registration certificate or filing certificate. Same brand often sells both industrial line and medical line. Look about the same, price differs by double. Difference is in that certificate.

When purchasing, have supplier show medical device registration certificate. Using equipment without qualification, health regulators come to inspect and it's compliance risk. Something goes wrong, liability determination is more troublesome. Opening a clinic costs $50,000+ minimum investment. Compressor system max few thousand dollars. Saving money at this link doesn't pay.

Dental compressor cabinet

Cattani AC200 three-chair configuration around $3,000. AC300 five-six chair around $4,000. Domestic Hongrun same spec models about 30% cheaper. Dürr more expensive. $5,000-6,000 and up. German original, quality and after-sales really are different. This price range is small share of clinic total investment. Equipment picked right, after that it's routine maintenance: change elements on time, drain condensate daily, send receiver for inspection when due. System isn't complicated. Maintenance done right, using ten years is no problem.

Footer Component - SOLLANT